JQ-331 is an aluminum-focused degreaser for pure aluminum, aluminum alloys and precision aluminum die-cast parts. Validate each alloy and surface finish. Use at room temperature, rinse thoroughly and dry promptly. It is not an oxide-scale remover or etching treatment. Material focus: aluminum and aluminum alloys; other materials are not assumed suitable.
| Item | Specification |
|---|---|
| Model | JQ-331 |
| Appearance | Colorless, transparent liquid. |
| pH (brochure value) | ≥7 |
| Pack sizes | 5 kg / 25 kg |
| Shelf life | 24 months |
The brochure does not specify pH test conditions; these values are not working-bath pH setpoints.
Add 3–5 parts water to one part concentrate. Soak, spray or wipe at room temperature; use the stated 3–6 minutes as a starting point validated by testing. Adjust concentration or time gradually for heavy soils; avoid uncontrolled extended soaking. Rinse thoroughly and dry promptly. Validate downstream requirements before coating, bonding or anodizing.
Wear protective gloves and goggles. Keep away from children. Avoid eye contact and prolonged skin contact; rinse eyes immediately with plenty of water after contact. Check for discoloration, gloss changes, pitting and dimensional requirements before full-scale cleaning.
| Item | Specification |
|---|---|
| Model | JQ-331 |
| Appearance | Colorless, transparent liquid. |
| pH (brochure value) | ≥7 |
| Pack sizes | 5 kg / 25 kg |
| Shelf life | 24 months |
The brochure does not specify pH test conditions; these values are not working-bath pH setpoints.
Add 3–5 parts water to one part concentrate. Soak, spray or wipe at room temperature; use the stated 3–6 minutes as a starting point validated by testing. Adjust concentration or time gradually for heavy soils; avoid uncontrolled extended soaking. Rinse thoroughly and dry promptly. Validate downstream requirements before coating, bonding or anodizing.
Wear protective gloves and goggles. Keep away from children. Avoid eye contact and prolonged skin contact; rinse eyes immediately with plenty of water after contact. Check for discoloration, gloss changes, pitting and dimensional requirements before full-scale cleaning.